<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-23 05-22-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.90 MHz 4/5, 54 dBuV RFM
Pilot RDS Phase Difference
7.1 kHz 4.2 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
15 kHz 72 kHz 10060 0,1093
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,5 dBr 8,01 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RFM " F212 0 (No PTY) 1 0 0 1 5:22, 23.07.2025
RT
"RFM - BOB MARLEY - Buffalo soldier "
AF EON
91.3, 93.3, 93.6, 94.3, 95.7, 97.3, 99.8, 101.6, 101.7, 102.4, 102.6, 103.8, 103.9, 104.1, 106.2, 107.0, 107.4 MHz -
FM Scope Station: 103.90 MHz, signal: 4/5 (54 dBuV) Max at: 72 kHz MIN: 15 kHz % above 75 kHz: 0,1093 Acquired: 2025/07/23 5:21:20 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,6 dBr MIN: 7,5 dBr AVE: 8,01 dBr % above 10,2 dBr: 0,0 Last value: 7,5 dBr (2025/07/23 5:21:20) Station: 103.90 MHz, signal: 4/5 (54 dBuV) 05:14 05:15 05:16 05:17 05:18 05:19 05:20 05:21 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality